Project

General

Profile

Actions

Defect #3130

open

Change of dynamically calculated manager will not execute provisioning on subordinate when differential synchronization is used

Added by Roman Kučera over 2 years ago. Updated almost 2 years ago.

Status:
New
Priority:
Normal
Assignee:
Jan Potočiar
Category:
Synchronization
Target version:
Start date:
06/02/2022
Due date:
% Done:

0%

Estimated time:
Affected versions:
Owner:

Description

Synchronization from HR is differential.
User A has dynamically calculated manager based on org structure for example.
Manager for User A has changed, but no provisioning on User A was executed. As a result of this behavior, User A has outdated value in connected systems.

Workaround
  • Don't use differential sync is this is issue for you
  • Resave User A in IdM
Actions #1

Updated by Tomáš Doischer about 2 years ago

  • Target version changed from 13.0.0 to 12.4.0
Actions #2

Updated by Tomáš Doischer almost 2 years ago

  • Target version changed from 12.4.0 to 13.1.0
Actions #3

Updated by Tomáš Doischer almost 2 years ago

  • Assignee changed from Peter Štrunc to Jan Potočiar
Actions